Hi Leif, Jurgen, and all,
Leif Asbrink wrote:
> Linrad only understands the original call3.txt format as
> supplied with the original wsjt program.
>
> I have no idea what the different formats are now and
> whether it would be easy or difficult to update
> Linrad to understand them all.
The format of CALL3.TXT has never changed. It's the same as
it has always been.
Jurgen wrote:
> Failed to read CALL3.TXT excessive line length or field to long
> A maximum of 32 callsigns are loaded
> Any suggestions ?
This error message seems perfectly clear. Linrad objects to
an unusually long line, probably around line number 33.
(Perhaps in line 35 or 36, as there are likely to be a few
header lines at the top.)
Edit the long line to remove unnecessary stuff near the end.
Linrad (and WSJT, for that matter) use only the first two
or three comma-separated fields. Then read the file into
Linrad again.
Depending on what you have in your file, you may need to do
edit more than one extra-long line.
-- 73, Joe, K1JT
--