[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[linrad] Re: PTS 310 synthesizer
- Subject: [linrad] Re: PTS 310 synthesizer
- From: David Garnier <wi.rr.com; dgarnier@xxxxxxxxxxxxxxxx>
- Date: Sat, 25 Mar 2006 13:35:47 -0600
Rein,
I have a PTS120 and I was surprised to find that it did not contain an
on-board
10 Mhz reference oscillator, I wasn't to pleased. An on board
oscillator appears to
have been an option. These things maybe normally supplied from a master
10 Mhz
source depending on the usage.
The PTS's logic circuitry is mostly composed of the old style ECL logic,
(I wish I had
some sort of schematic for mine.) There was no easy way to generate or
steal an
+5 or +12 voltage source from the PTS's power supply to run an oven
oscillator.
Ended up adding a small analog supply inside the PTS to power the oven
oscillator.
I also added a mini-circuits 1:1 isolation transformer for coupling the
10 Mhz source
to the PTS.
Dave Garnier - wb9own
Rein A. Smit wrote:
Hello All,
I am looking for info on the PTS 310 Synthesizer.
My unit has no frequency selection switches , no/off and no phase
selection switch either.
I hard wired the remote switch for 28150 Khz. with the latching and
remote operation
enabled just to test it.
When I turn the unit on, I get a broad band noise, quite strong, not
a trace of any
generated signal and no 10 MHz signal from the internal standard.
Removing the 50 pin remote connector has no effect either.
73 Rein W6/PA0ZN
#############################################################
This message is sent to you because you are subscribed to
the mailing list <linrad@xxxxxxxxxxxxxxxxxxxxx>.
To unsubscribe, E-mail to: <linrad-off@xxxxxxxxxxxxxxxxxxxxx>
To switch to the DIGEST mode, E-mail to
<linrad-digest@xxxxxxxxxxxxxxxxxxxxx>
To switch to the INDEX mode, E-mail to
<linrad-index@xxxxxxxxxxxxxxxxxxxxx>
Send administrative queries to <linrad-request@xxxxxxxxxxxxxxxxxxxxx>
#############################################################
This message is sent to you because you are subscribed to
the mailing list <linrad@xxxxxxxxxxxxxxxxxxxxx>.
To unsubscribe, E-mail to: <linrad-off@xxxxxxxxxxxxxxxxxxxxx>
To switch to the DIGEST mode, E-mail to <linrad-digest@xxxxxxxxxxxxxxxxxxxxx>
To switch to the INDEX mode, E-mail to <linrad-index@xxxxxxxxxxxxxxxxxxxxx>
Send administrative queries to <linrad-request@xxxxxxxxxxxxxxxxxxxxx>
LINRADDARNIL